ISO/IEC17025 Accredited Pipette Calibration Service
Our multi-tiered services are designed to allow you to meet your specific requirements while ensuring that you don’t have to pay for services that you don’t need. Our service regiment offers the most complete and technically valid conformity verification. Our pipette service complies with the requirements of ISO 8655, ISO/IEC 17025, GLP/GMP, FDA, and 21CFR. We pride ourselves on delivering accurate and precise calibrations that fit your laboratory needs.

Instrument Evaluation
Instrument evaluation tolerances and calibration intervals are determined by the customer and should be based on the accuracy and precision requirements of their applications and operations
Note to Customers
CLC Calibration, is accredited by PJLA, an ILAC member and MRA signatory. It is the customer’s responsibility to ensure that this accreditation and certification of calibration results
ISO/Accredited Analytical Balance and Scale
CLC Calibration offers on-site balance and scale calibration services at our facility. We have the following balance calibration services.
Platinum Balance Calibration
This is an accredited calibration performed using NIST-traceable ASTM Class 1 weights. The documentation provided by us is fully compliant with ISO/IEC17025 requirements. Balances are checked for linearity, repeatability, eccentricity, and span.
Scales are calibrated using NIST-traceable ASTM Class 1, Class 2, or Class F weights, as applicable. We use the manufacturer’s specifications and tolerances unless specified by the customer.
NIST- traceable temperature and relative humidity meters are used to determine the environmental conditions. A calibrated label with a customer-specified expiration interval is affixed to the instrument after the balance has been calibrated.
ISO/Temperature Calibration Service
CLC Calibration provides calibration services for liquid-in-glass, digital, bi-metal, thermocouple, thermistor, and RTD thermometers. Temperature instruments are calibrated by the comparison method with instruments traceable to the National Institute of Standards and Technology (NIST).
We follow the ITS-90 reference guide specifications, and tolerances are those published by the manufacturer unless specified by the customer. Standard calibration includes three measurement points and includes comprehensive calibration documentation and a calibration label affixed to the instrument. Additional measurement points are available for an additional charge per point.